{"product_id":"gvda-gd105c-socket-tester-uk-plug","title":"GVDA GD105C Socket Tester UK Plug","description":"\u003ch2\u003eGVDA GD105C Socket Tester – UK Plug with Voltage Display \u0026amp; RCD\/GFCI Test\u003c\/h2\u003e\n\n\u003cp\u003eThe GVDA GD105C is a professional mini socket tester designed for UK standard power outlets. It quickly and accurately detects wiring faults including missing earth, missing neutral, live\/neutral reversal, and more. Featuring an LCD voltage display and built-in RCD (30mA) and GFCI (\u0026gt;5mA) test functions, this compact portable tool is ideal for electricians, homeowners, and safety inspectors to verify correct socket wiring and leakage protection.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features:\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e1) \u003cstrong\u003eMini Portable Design\u003c\/strong\u003e – Compact and lightweight, easy to carry and simple to use\u003c\/li\u003e\n  \u003cli\u003e2) \u003cstrong\u003eUK Standard Plug\u003c\/strong\u003e – Designed for UK three-pole power sockets (EU\/US versions also available)\u003c\/li\u003e\n  \u003cli\u003e3) \u003cstrong\u003eLCD Voltage Display\u003c\/strong\u003e – Shows real-time socket voltage on a high-definition screen, clearly visible in dark environments\u003c\/li\u003e\n  \u003cli\u003e4) \u003cstrong\u003eRCD Test (30mA)\u003c\/strong\u003e – Tests residual current device functionality (requires 220V±20V)\u003c\/li\u003e\n  \u003cli\u003e5) \u003cstrong\u003eGFCI Test (\u0026gt;5mA)\u003c\/strong\u003e – Tests ground fault circuit interrupter (requires 110V±20V)\u003c\/li\u003e\n  \u003cli\u003e6) \u003cstrong\u003eWide Voltage Range\u003c\/strong\u003e – Operates with 48V-250V AC, 45-65Hz\u003c\/li\u003e\n  \u003cli\u003e7) \u003cstrong\u003eQuick \u0026amp; Accurate Detection\u003c\/strong\u003e – Identifies common wiring faults instantly\u003c\/li\u003e\n  \u003cli\u003e8) \u003cstrong\u003eWide Application\u003c\/strong\u003e – Suitable for schools, laboratories, factories, and home use\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eSpecifications:\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eModel\u003c\/td\u003e\n      \u003ctd\u003eGD105C\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePlug Standard\u003c\/td\u003e\n      \u003ctd\u003eUK Plug (EU\/US versions also available)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOperating Voltage\u003c\/td\u003e\n      \u003ctd\u003e48V – 250V AC, 45-65Hz\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMeasurement Voltage\u003c\/td\u003e\n      \u003ctd\u003e48V – 250V AC, 45-65Hz\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eVoltage Accuracy\u003c\/td\u003e\n      \u003ctd\u003e±(2.0% + 2 digits)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eRCD Test Current\u003c\/td\u003e\n      \u003ctd\u003e≥30mA\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eRCD Working Voltage\u003c\/td\u003e\n      \u003ctd\u003e220V ± 20V\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eGFCI Test Current\u003c\/td\u003e\n      \u003ctd\u003e\u0026gt;5mA\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eGFCI Working Voltage\u003c\/td\u003e\n      \u003ctd\u003e110V ± 20V\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eAltitude\u003c\/td\u003e\n      \u003ctd\u003e≤2000m\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eItem Dimensions\u003c\/td\u003e\n      \u003ctd\u003e68 × 65 × 60 mm (2.68 × 2.56 × 2.36 in)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eDetected Wiring Faults:\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCorrect wiring\u003c\/strong\u003e – all indicators normal\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMissing earth \/ ground\u003c\/strong\u003e – no earth connection\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMissing neutral\u003c\/strong\u003e – neutral wire disconnected\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLive \/ neutral reverse\u003c\/strong\u003e – live and neutral wires swapped\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLive \/ earth reverse\u003c\/strong\u003e – live and earth wires swapped\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMissing live\u003c\/strong\u003e – live wire disconnected\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eHow to Use:\u003c\/h3\u003e\n\n\u003cp\u003e\u003cstrong\u003eWiring \u0026amp; Voltage Test:\u003c\/strong\u003e\u003c\/p\u003e\n\u003col\u003e\n  \u003cli\u003eInsert the tester into a standard UK 3-pole power socket\u003c\/li\u003e\n  \u003cli\u003eObserve the indicator light pattern to identify wiring status\u003c\/li\u003e\n  \u003cli\u003eRead the real-time voltage on the LCD display\u003c\/li\u003e\n  \u003cli\u003eIf a wiring fault is detected, consult a professional electrician for repair\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003cp\u003e\u003cstrong\u003eRCD \/ GFCI Test:\u003c\/strong\u003e\u003c\/p\u003e\n\u003col\u003e\n  \u003cli\u003eInsert the tester into a correctly wired socket\u003c\/li\u003e\n  \u003cli\u003ePress and hold the RCD\/GFCI test button\u003c\/li\u003e\n  \u003cli\u003eThe RCD (30mA) or GFCI (\u0026gt;5mA) should trip within specified parameters\u003c\/li\u003e\n  \u003cli\u003eIf the safety switch does not trip, the leakage protection has failed – seek professional electrician assistance\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eWhere It Can Be Used:\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHome electrical safety\u003c\/strong\u003e – check all household sockets for correct wiring\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProfessional electrician work\u003c\/strong\u003e – verify socket installations after repairs\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSchools \u0026amp; laboratories\u003c\/strong\u003e – ensure electrical safety in educational facilities\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFactories \u0026amp; industrial sites\u003c\/strong\u003e – regular electrical system checks\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBuilding inspections\u003c\/strong\u003e – test new or renovated electrical circuits\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRental property compliance\u003c\/strong\u003e – safety verification for landlords\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003ePackage Includes:\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e1 × GVDA GD105C Socket Tester (UK Plug)\u003c\/li\u003e\n  \u003cli\u003e1 × User Manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eNote: EU and US plug versions (GD105A\/GD105B) are also available – select the correct plug type for your region.\u003c\/em\u003e\u003c\/p\u003e","brand":"GVDA","offers":[{"title":"Default Title","offer_id":56102584844673,"sku":"GVDA-ST-105C-UK","price":6.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0656\/3486\/1290\/files\/gvda-gd105c-socket-tester-uk-plug-socket-tester-gvda-4590097.jpg?v=1787823158","url":"https:\/\/ampanova.shop\/products\/gvda-gd105c-socket-tester-uk-plug","provider":"AMPANOVA","version":"1.0","type":"link"}